Fowrise-DOUBLE-SIDED AIR-COOLED FAN

The double-sided air cooler series is a cooling device used in food processing rooms, with air outlets from both sides and soft air supply, suitable for use at temperatures above 8 ℃ . (If the storage temperature is below 8 ℃ , a defrosting electric heater needs to be installed)

Share:

💎Description&Main Features:

1、The shell is made of aluminum plate, coated with plastic on the surface, corrosion-resistant, and has a beautiful appearance;

2、 The coil adopts a staggered arrangement and utilizes mechanical expansion to tightly bond the copper tube with the aluminum fins, resulting in good heat transfer efficiency;

3、 Adopting an external rotor motor, double-sided side blowing, soft air supply, and low noise;

4、For products with special purposes, please contact the company’s various distribution offices.

💎Main technical specifications:

1、DOUBLE-SIDED AIR-COOLED FAN-High temperature DL type

DOUBLE-SIDED AIR-COOLED FAN-High temperature DL type
High temperature standard ceiling type air cooler parameters
 Model DL20( two ) DL25( three) DL40( three ) DL55( three ) DL80( three) DL105( three) DL135( three ) DL160( three ) DL185( four) DL220( four)
Nominal cooling  capacity(W) 4300 5300 8400 12000 17000 23000 29500 35000 40000 46000
Nominal area(m²) 20 25 40 55 80 105 135 160 185 220
Refrigerant inlet/outlet pip(mm)     ø12/ø19     ø12/ø19     ø16/ø25     ø16/ø25     ø19/ø32     ø19/ø32     ø22/ø38     ø19/ø38     ø25/ø42     ø25/ø42
Copper tube (φ12.7)* Arrange 4*6 4*6 4*8 6*8 6*10 8*10 8*10 10*10 8*12 8*12
Fan parameters Air volume( m³/h) 2900 4350 7350 7350 9750 9750 13950 13950 18600 18600
numbe(N) 2 3 3 3 3 3 3 3 4 4
 Blade
diameter(mm)
    ø300     ø300     ø350     ø350     ø400     ø400     ø450     ø450     ø450     ø450
Voltage(V) 220/380 220/380 220/380 220/380 220/380 220/380 380 380 380 380
Power(W)   2*78   3*78   3*125   3*125   3*200   3*200   3*252   3*252 4*252 4*252
Electric defrost Winged defrosting Power(KW) 1.65 2.55 2.55 2.55 5.8 5.8 7 7 8 8
Power of water receiving tray(KW) 1.65 2.55 2.55 2.55 2.9 2.9 3.5 3.5 4 4.5
 Voltage(V) 220 220 220 220 220 220 220 220 220 220
Length*Width*Height(L*K*H) 1160*715*320 1660*715*320 1660*810*390 1660*810*390 1860*925*490 1860*925*490 2160*1040*490 2160*1040*490 2460*1040*565 2760*1040*565
Position and size of ceiling installation holes(D1*D2*E1*E2*E3) 665*925 665*1425 760*1425 760*1425 875*1625 875*1625 990*1925*641.5*641.5 990*1925*641.5*641.5 990*2225*556*556*556 990*2525*631*631*631
Outer diameter of
drainage pipe
G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2
Distance from wall(mm) 300 300 300 300 300 300 300 300 300 300
REMARKS:
a. High temperature DL type (cooling capacity of R22 at T library=0° C ), sheet spacing: 4.5mm
b.*When Tr=-25Cand △ t=10C,R134a energy should multiply correction factor f,that is QoR134a=QoR22 Xf.

2、T DOUBLE-SIDED AIR-COOLED FAN-medium temperature DD type

 DOUBLE-SIDED AIR-COOLED FAN-medium temperature DD type
Technical parameters of medium temperature standard ceiling air cooler
 Model DD15( two ) DD22( three) DD30( three) DD40( three ) DD60( three ) DD80( three ) DD100( three ) DD120( three ) DD140( four ) DD160( four )
Nominal cooling  capacity(W) 2600 3900 5300 7000 11000 14000 18000 21000 25000 28000
Nominal area(m²) 15 22 30 40 60 80 100 120 140 160
Refrigerant inlet/outlet pip(mm)     ø12/ø19     ø12/ø19     ø16/ø25     ø16/ø25     ø19/ø32     ø19/ø32     ø22/ø38     ø19/ø38     ø25/ø42     ø25/ø42
Copper tube (φ12.7)* Arrange 4*6 4*6 4*8 6*8 6*10 8*10 8*10 10*10 8*12 8*12
Fan parameters Air volume( m³/h) 2900 4350 7350 7350 9750 9750 13950 13950 18600 18600
numbe(N) 2 3 3 3 3 3 3 3 4 4
Blade diameter(mm)     ø300     ø300     ø350     ø350     ø400     ø400     ø450     ø450     ø450     ø450
Voltage(V) 220/380 220/380 220/380 220/380 220/380 220/380 380 380 380 380
Power(W)   2*78   3*78   3*125   3*125   3*200   3*200   3*252   3*252 4*252 4*252
Electric defrost Winged defrosting Power(KW) 1.65 2.55 2.55 5.1 8.8 8.8 10.5 10.5 12 13.5
Power of water receiving tray(KW) 1.65 2.55 2.55 2.55 2.9 2.9 3.5 3.5 4 4.5
 Voltage(V) 220 220 220 220 220 220 220 220 220 220
Length*Width*Height(L*K*H) 1160*715*320 1660*715*320 1660*810*390 1660*810*390 1860*925*490 1860*925*490 2160*1040*490 2160*1040*490 2460*1040*565 2760*1040*565
Position and size of ceiling installation holes(D1*D2*E1*E2*E3) 665*925 665*1425 760*1425 760*1425 875*1625 875*1625 990*1925*641.5*641.5 990*1925*641.5*641.5 990*2225*556*556*556 990*2525*631*631*631
Outer diameter of drainage pipe G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2
Distance from wall(mm) 300 300 300 300 300 300 300 300 300 300
REMARKS:
a. Medium temperature DD type (cooling capacity of R22 at T-library=-18 ° C) Plate pitch: 6.5mm
b.*When Tr=-25Cand △ t=10C,R134a energy should multiply correction factor f,that is QoR134a=QoR22 Xf.

3、 DOUBLE-SIDED AIR-COOLED FAN- low-temperature DJ type

 DOUBLE-SIDED AIR-COOLED FAN- low-temperature DJ type
 Technical parameters of low-temperature standard ceiling air cooler
 Model DJ15( three) DJ20( three ) DJ30( three) DJ40( three ) DJ55( three ) DJ70( three ) DJ85( three ) DJ100(  four) DJ115(  four)
Nominal cooling  capacity(W) 2300 3100 4700 6200 8500 11000 13000 16000 18000
Nominal area(m²) 15 20 30 40 55 70 85 100 115
Refrigerant inlet/outlet pip(mm)     ø12/ø19     ø16/ø25     ø16/ø25     ø19/ø32     ø19/ø32     ø22/ø38     ø19/ø38     ø25/ø42     ø25/ø42
Copper tube (φ12.7)* Arrange 4*6 4*8 6*8 6*10 8*10 8*10 10*10 8*12 8*12
Fan parameters Air volume( m³/h) 4350 7350 7350 9750 9750 13950 13950 18600 18600
numbe(N) 3 3 3 3 3 3 3 4 4
Blade diameter(mm)     ø300     ø350     ø350     ø400     ø400     ø450     ø450     ø450     ø450
Voltage(V) 220/380 220/380 220/380 220/380 220/380 380 380 380 380
Power(W)   3*78   3*125   3*125   3*200   3*200   3*252   3*252 4*252 4*252
Electric defrost Winged defrosting Power(KW) 2.55 2.55 5.1 8.8 8.8 10.5 10.5 12 13.5
Power of water receiving tray(KW) 2.55 2.55 2.55 2.9 2.9 3.5 3.5 4 4.5
Voltage(V) 220 220 220 220 220 220 220 220 220
Length*Width*Height(L*K*H) 1660*715*320 1660*810*390 1660*810*390 1860*925*490 1860*925*490 2160*1040*490 2160*1040*490 2460*1040*565 2760*1040*565
Position and size of ceiling installation holes(D1*D2*E1*E2*E3) 665*1425 760*1425 760*1425 875*1625 875*1625 990*1925*641.5*641.5 990*1925*641.5*641.5 990*2225*556*556*556 990*2525*631*631*631
Outer diameter of drainage pipe G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2 G1*2
Distance from wall(mm) 300 300 300 300 300 300 300 300 300
REMARKS:
a. Low temperature DJ type (cooling capacity of R22 at T-library=-25 ° C) sheet spacing: 9.0mm
b.*When Tr=-25Cand △ t=10C,R134a energy should multiply correction factor f,that is QoR134a=QoR22 Xf.

💎Applicable Scene